J152 Series UL Approved Relay

 

Features

Datasheet in PDF

Switching Capacity up to 10A
Low Coil Power Consumption
High Contact Load
Strong Resistance to Shock & Vibration

 

Contact Rating 2 & 3 Pole: 10A@220VAC & 28VDC General Purpose
4 Pole: 5A@220VAC & 28VDC General Purpose

 

Dimensions Contact
Arrangement
Contact Material Coil Voltage Coil Power Contact Resistance
27.0 x 21.0 x 35.0 2A, 3A, 4A, 2B, 3B, 4B, 2C, 3C, 4C AgCdO 12VDC, 24VDC, 110VDC, 12VAC, 24VAC, 110VAC, 120VAC, 220VAC DC: .90W; AC 1.2W < 50m Ohm

 

 

Insulation Resistance Electrical Life Mechanical Life Dielectric Strength
100M Ohm @ 500VDC 100K cycles, 200K cycles, 500K cycles 10M cycles, 20M cycles

Contact-to-Contact: 1500V rms

Contact-to-Coil: 1500V rms

 

 

Operating Temperature Mounting Methods Agency Approvals
-40C to 85C PC Pin, Solder Lug E197851

 

 

Dimensional Drawing


 

Schematic


 

PC Board Layout